Switching and Analyzing Magnets

Switching Magnets

Below are some of the switching magnets NEC has provided. Custom magnets may be available to meet your specific needs. Chamber and stands for these magnets are typically provided as well. Typical chamber exit ports are 0o, ±15o, ±30o, ±45o (except SW2). Other angles may be available upon request.

P (ME/z2) amu-MeV

Gap (pole to pole)

Bending Radius

Max Current/Voltage 

Cooling Water 

Weight (w/o chamber)

SW1200

2BA020070

1289 at 15o
328 at 30o
150 at 45o
34 mm 359.1 cm at 15o
181.1 cm at 30o
122.5 cm at 45o
184A at 45V 2.8 GPM (11 l/m) 24,630 lbs
(11,200 kg)

SW600

2BA020060

610 at 15o
156 at 30o
70.3 at 45o
34 mm 245.9 cm at 15o
124.0 cm at 30o
83.9 cm at 45o
180A at 34V 2.1 GPM (8 l/m) 14,340 lbs
(6,520 kg)

SW300

2BA017470

350 at 15o
91 at 30o
41 at 45o
31.8 mm 178.6 cm at 15o
90.1 cm at 30o
60.9 cm at 45o
100A at 40V 2 GPM (7.6 l/m) 4,770 lbs
(2,160 kg)

SW150

2BA017121

150 at 15o
38 at 30o
17 at 45o
27 mm 123.4 cm at 15o
62.2 cm at 30o
42.2 cm at 45o
100A at 40V 1 GPM (4 l/m) 2,860 lbs
(1,300 kg)

SW70*

2BA017370

70 at 15o
20 at 30o
32 mm 90.65 cm at 15o
45.7 cm at 30o
65A at 30V .75GPM (2.8 l/m) 1,930 lbs
(875 kg)

SW20**

2BA017080

82 at 15o
21 at 30o
32 mm 90.6cm at 15o
45.7 cm at 30o
30.9cm at 45o
65A at 30V 0.7 GPM (2.7 l/m) 2,005 lbs
(910 kg)

SW6

2BA017240

25.56 at 15o
6.5 at 30o
2.97 at 45o
30.5 mm 80.6 cm at 15o
40.6 cm at 30o
27.5 cm at 45o
55A at 40V 0.6 GPM (2.5 l/m) 726 lbs
(329 kg)

SW2

2BA013270

16.5 at 2.5o 19mm 291cm at 2.5o 20A at 20V N/A 90 lbs
(40kg)
Cooling water pressure drop is 4 kg/cm2 (60 psi)

* For HE end analyzing use (pole scribe marks differ)
**For inflection use (pole scribe marks differ)

Analyzing Magnets

NEC also provides Analyzing Magnets. Below are specifications for a few of our 90 degree magnets, how-ever many other magnets are available. If interested, please inform us of the needed specifications and we can suggest a magnet model or custom magnet suitable for your needs.

Mass Energy Product (MEP) 5 14.7 31.5 176
Radius  12” (30.5cm) 29.5” (75cm) 29.5” (75cm) 50” (1270mm)
Pole Gap 1.125” (2.86cm) 2” (50.8cm) 2” (50.8cm) 1” (28mm)
Pole End Angle  28.7o 27.54o 28.5o 27.3o
Current  40A at 60V 92A at 45V 179A 289A at 42V
Water Cooling  0.7GPM (2.5 l/min) 1.3 GPM (5 l/min) 2.6 GPM (10 l/min) 157 GPM (595 l/min)
Weight  2,000 lbs (910 kg) 8,800 lbs (4,000kg) 11,600lbs (5,275 kg) 9,040 lbs (4,100kg)
Chamber  2GW070030 2GW067270 2GW067430 2GW054610
Cooling water pressure drop is 4 kg/cm2 (60 psi)

Related Documents
Switching and Analyzing Magnets